Ivation
Overcooling / Thermostat Control Failure
Wine cooler is too cold and bottles are freezing near the back.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck relay on control board, Shorted temperature sensor, Sensor not properly attached to cabinet wall, Control board calibration fault
How to Fix / Troubleshooting
Safety: Unplug the Ivation wine cooler before accessing sensors or the control board.
Steps:
- Verify set temperature: Ensure the setpoint is appropriate for wine (typically 45–65°F). Adjust upward if set too low.
- Check sensor placement: Locate the cabinet thermistor and confirm it is firmly attached to the wall or evaporator as designed. Reattach with aluminum tape if loose.
- Test sensor: Measure resistance and compare to Ivation specs. Replace a shorted sensor with a new Ivation cabinet temperature sensor.
- Control board: If sensor is good and properly placed but overcooling persists, the control board relay may be stuck closed. Replace the Ivation main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Cabinet Temperature Sensor (Thermistor)
Check Price on Amazon