Ivation Overcooling / Thermostat Control Failure

Wine cooler is too cold and bottles are freezing near the back.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck relay on control board, Shorted temperature sensor, Sensor not properly attached to cabinet wall, Control board calibration fault

How to Fix / Troubleshooting

Safety: Unplug the Ivation wine cooler before accessing sensors or the control board.

Steps:

  • Verify set temperature: Ensure the setpoint is appropriate for wine (typically 45–65°F). Adjust upward if set too low.
  • Check sensor placement: Locate the cabinet thermistor and confirm it is firmly attached to the wall or evaporator as designed. Reattach with aluminum tape if loose.
  • Test sensor: Measure resistance and compare to Ivation specs. Replace a shorted sensor with a new Ivation cabinet temperature sensor.
  • Control board: If sensor is good and properly placed but overcooling persists, the control board relay may be stuck closed. Replace the Ivation main control board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cabinet Temperature Sensor (Thermistor)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements