Ivation Insufficient Cooling / Loss of Capacity

Wine cooler runs but does not reach set temperature; only cools slightly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coils, Weak or leaking refrigerant charge (compressor models), Failing Peltier module, Blocked internal airflow, Door gasket leak

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning or removing panels.

Steps:

  • Clean condenser coils: On compressor Ivation models, remove the rear panel and gently clean dust from the condenser coils with a brush or vacuum.
  • Check fans: Ensure both condenser and internal circulation fans are running and unobstructed.
  • Inspect door gasket: Close the door on a sheet of paper and gently pull. If it slides out easily in multiple spots, the gasket may be leaking. Replace with a Ivation door gasket.
  • Reduce load and spacing: Avoid overpacking bottles; leave space between bottles and walls for airflow.

If cooling remains weak after these steps, the sealed system (compressor/refrigerant) or Peltier module may be failing and requires professional service.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Gasket
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements