Ivation
Insufficient Cooling / Loss of Capacity
Wine cooler runs but does not reach set temperature; only cools slightly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coils, Weak or leaking refrigerant charge (compressor models), Failing Peltier module, Blocked internal airflow, Door gasket leak
How to Fix / Troubleshooting
Safety: Unplug the unit before cleaning or removing panels.
Steps:
- Clean condenser coils: On compressor Ivation models, remove the rear panel and gently clean dust from the condenser coils with a brush or vacuum.
- Check fans: Ensure both condenser and internal circulation fans are running and unobstructed.
- Inspect door gasket: Close the door on a sheet of paper and gently pull. If it slides out easily in multiple spots, the gasket may be leaking. Replace with a Ivation door gasket.
- Reduce load and spacing: Avoid overpacking bottles; leave space between bottles and walls for airflow.
If cooling remains weak after these steps, the sealed system (compressor/refrigerant) or Peltier module may be failing and requires professional service.
Advertisements
Repair Difficulty
Medium
3/5