Possible Causes
High ambient humidity, Door gasket not sealing properly, Failed heated door or mullion (if equipped), Poor ventilation around unit
How to Fix / Troubleshooting
Safety: No internal electrical work is typically required; unplug if removing trim.
Steps:
- Check room conditions: High humidity environments will naturally cause more condensation. Use a dehumidifier if possible.
- Inspect gasket: Ensure the door gasket seals fully. Replace if torn or warped.
- Ventilation: Confirm proper airflow around the unit per JennAir installation guidelines.
- Heated door (if equipped): If your model has a heated door edge and it is not warming, the heater circuit or control may be faulty and should be checked by a technician.