F5
JennAir Zone Damper or Airflow Control Fault (Dual-Zone Models)

Wine cooler displays F5 and one zone may not cool while the other operates normally.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck or failed air damper motor, Broken damper door, Obstructed air channel between zones, Control board damper driver failure

How to Fix / Troubleshooting

Safety: Disconnect power before accessing internal ducting or dampers.

Steps:

  • Identify affected zone: Determine which zone is too warm or too cold.
  • Access damper assembly: On some JennAir dual-zone models, a motorized damper controls airflow between zones. Remove interior panels to locate it.
  • Inspect damper door: Check that the damper door moves freely and is not broken or blocked by insulation or debris.
  • Test damper motor: With a multimeter, check for continuity in the motor windings. If open, replace the damper motor assembly.
  • Check wiring: Verify the harness from the control board to the damper is intact and connectors are secure.
  • Control board: If the damper motor is good but never receives power when the zone calls for cooling, the control board may be defective.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Damper Assembly
Check Price on Amazon