JennAir
Complete Cooling System Failure
Wine cooler not cooling at all; interior is room temperature, but lights and display work.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor, Open compressor start relay or overload, Severe refrigerant leak, Faulty main control board not energizing compressor
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing the rear compartment. Refrigerant work must be done by an EPA-certified technician.
Steps:
- Listen for compressor: With power on (before unplugging), check if the compressor hums or clicks. No sound suggests it is not being energized.
- Check condenser fan: If the condenser fan does not run, the compressor may also not be receiving power.
- Test start components: See E5 for testing the compressor start relay and overload. Replace if defective.
- Inspect control board: If start components are good but the compressor never receives voltage, the main control board may be faulty and should be replaced.
- Sealed system diagnosis: If the compressor runs but there is no cooling and the condenser stays cool, there may be a refrigerant leak or internal restriction. This requires professional sealed system service.
Advertisements
Repair Difficulty
Professional Required
5/5