F2
Kenmore
Lower Zone Temperature Sensor Fault
Kenmore dual-zone wine cooler shows F2 on display; lower zone temperature is unstable or not cooling.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed lower zone thermistor, Disconnected sensor harness, Damaged wiring near lower evaporator
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing lower zone panels.
Steps to address F2 (lower zone):
- Confirm zone mapping: Verify that F2 corresponds to the lower zone on your Kenmore model.
- Access lower zone sensor: Remove lower shelves and any interior panel covering the sensor channel.
- Inspect wiring: Look for pinched or cut wires, especially near the divider between zones.
- Test thermistor: Disconnect and measure resistance at room temperature. Replace the lower zone temperature sensor (thermistor) if readings are open, shorted, or out of spec.
- Reassemble and test: Restore power and monitor the lower zone for several hours to ensure stable temperature and that F2 clears.