E8
Kismile
Compressor Drive or Inverter Error (on inverter-driven Kismile models)
Display shows E8 and the unit may not cool; compressor may not start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty inverter module (if separate), Shorted compressor windings, Loose compressor harness, Main control board compressor driver failure
How to Fix / Troubleshooting
Safety: Unplug the unit. Compressor and inverter circuits carry high voltage; if you are not experienced, contact a professional.
- Access rear compartment: Remove the rear lower panel to expose the compressor and control electronics.
- Check wiring: Inspect the harness from the main board or inverter module to the compressor for loose plugs or damaged insulation.
- Visual inspection of inverter (if present): Look for burn marks, bulging components, or a burnt smell on the inverter module.
- Basic compressor test: With power disconnected, measure resistance between compressor terminals. All three windings should show similar, low resistance and no continuity to ground. If windings are shorted to ground, the compressor is failed.
- Replace inverter or board: If the compressor tests good but E8 persists, replace the Kismile inverter module or main control board as configured on your model.
- Professional service: If the compressor is shorted or open, the sealed system requires replacement by a licensed refrigeration technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Inverter Module or Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.