L1
Kismile Low Temperature Alarm Condition

Display shows L1 and interior temperature is very low; bottles may be too cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect temperature setting, Stuck relay on main control board, Shorted temperature sensor reading too warm, Faulty control board not cycling compressor off

How to Fix / Troubleshooting

Safety: Use caution when working near live controls; unplug if removing covers.

  • Check set temperature: Verify the setpoint on the control panel. Adjust to a higher (warmer) temperature and wait several hours to see if the unit stabilizes.
  • Sensor check: If the display temperature seems inaccurate, inspect the cabinet temperature sensor for proper placement and damage. A sensor reading too warm can cause overcooling.
  • Power reset: Unplug the cooler for 5 minutes, then plug back in to reset the control board.
  • Observe compressor cycling: If the compressor runs continuously even when the set temperature is reached, the main control board relay may be stuck closed and should be replaced.
  • Replace faulty sensor or board: If sensor tests bad, replace it. If sensor is good and compressor never cycles off, replace the main control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board