Kismile Thermostat or Temperature Control Failure (Overcooling)

Wine cooler is too cold; bottles or beverages are near freezing even at normal settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted cabinet temperature sensor, Stuck compressor relay on main control board, Incorrect temperature calibration, Control board firmware fault

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors or the control board.

  • Verify settings: Increase the set temperature and monitor for several hours to see if the interior warms.
  • Check sensor placement: Ensure the cabinet temperature sensor is not touching the evaporator coil directly, which can cause false low readings.
  • Test sensor: Measure resistance of the sensor at known temperatures. Replace if readings are out of specification.
  • Inspect control board: If the compressor runs continuously regardless of temperature, the main control board relay may be stuck and should be replaced.
  • Board replacement: Install a new OEM Kismile main control board if sensor replacement does not correct overcooling.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Temperature Sensor (NTC Probe)
Check Price on Amazon

We may earn a commission from links on this page.