E16
KitchenAid
Dual-Zone Diverter Damper / Air Baffle Fault
Wine cooler shows E16 and the unit may not cool one of the zones properly (dual-zone models)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or broken air damper motor, Obstructed air channels between zones, Failed damper position sensor, Control board damper output failure
How to Fix / Troubleshooting
Safety: Unplug the unit before removing interior panels. Avoid forcing plastic dampers; they can break easily.
E16 is associated with the air damper that regulates airflow between zones.
- Step 1 – Identify affected zone: Determine whether the upper or lower zone is not reaching set temperature.
- Step 2 – Access damper: Remove shelves and interior trim near the partition between zones. Locate the damper assembly (often behind a small grille).
- Step 3 – Inspect for blockage: Check for bottles, packaging, or ice blocking the air passages or damper movement. Clear any obstructions.
- Step 4 – Test damper movement: With power briefly restored, change the temperature setting significantly and listen/feel for damper movement. Then unplug again.
- Step 5 – Replace damper: If the damper motor does not move or is noisy, replace the damper assembly. Ensure the gasket seals properly around the opening.
- Step 6 – Control board: If a new damper does not operate and wiring is intact, the main control board damper output may be faulty and should be replaced by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Air Damper / Diverter Assembly
Check Price on Amazon