E17
KitchenAid Refrigerant System Performance Fault

Wine cooler displays E17 and the compressor runs continuously but temperature does not drop sufficiently

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge due to leak, Restricted capillary tube or filter-drier, Weak compressor, Severely dirty condenser coil

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning or inspecting the rear components. Sealed system repairs involve refrigerant and must be performed by an EPA-certified technician.

E17 indicates that the cooling system is not achieving expected performance.

  • Step 1 – Clean condenser: Thoroughly vacuum and brush the condenser coil and ensure the condenser fan operates correctly.
  • Step 2 – Check door sealing: Inspect the door gasket for gaps, tears, or warping. Replace if it does not seal tightly all around.
  • Step 3 – Load and ventilation: Avoid overloading the cabinet and ensure air can circulate around bottles. Verify installation clearances.
  • Step 4 – Monitor temperatures: After cleaning and adjustments, allow 24 hours and measure internal temperature with an accurate thermometer.
  • Step 5 – Call a technician: If the compressor runs nearly nonstop and the unit still cannot reach set temperature, a sealed system issue (leak, restriction, weak compressor) is likely. Contact a KitchenAid-authorized service provider.
Advertisements

Repair Difficulty

Professional Required 5/5