Possible Causes

Stuck or failed air damper, Blocked air channel to lower zone, Separate lower-zone evaporator fan failure, Faulty lower-zone thermistor

How to Fix / Troubleshooting

Safety: Unplug the unit before removing interior panels.

  • Step 1 – Check air vents: Ensure vents between zones are not blocked by bottles or shelves.
  • Step 2 – Inspect damper: Access the damper assembly between zones and verify it moves freely. Replace if stuck or broken.
  • Step 3 – Verify lower fan: If the lower zone has its own fan, test it for operation and replace if not running.
  • Step 4 – Replace lower thermistor: If the lower zone temperature reading is inaccurate, replace the lower-zone thermistor.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Air Damper / Lower-Zone Evaporator Fan