Temperature Calibration / Sensor Placement Issue
Temperature display does not match actual temperature measured with a thermometer.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Sensor located too close to cold plate or door, Sensor not clipped properly, Aging NTC sensor drifting out of spec, Control board calibration offset
How to Fix / Troubleshooting
Unplug the cooler before moving sensors.
Steps:
- Verify with accurate thermometer: Place a reliable thermometer in the center of the cabinet away from walls and compare readings after several hours of stable operation.
- Adjust sensor position: If the sensor is touching the cold plate or near the door, reposition it to a more central location on the rear wall using the original clip or a new mount.
- Replace sensor: If readings remain significantly off, replace the cabinet temperature sensor.
- Board calibration: Some models allow minor calibration via service mode; consult the service manual. Otherwise, a faulty main control board may need replacement.