La Sommeliere
Temperature Calibration / Sensor Drift
Temperature displayed on the control panel does not match an independent thermometer placed inside the cabinet.
Advertisements
Possible Causes
Aging NTC sensor, Sensor not in correct airflow, Control board calibration offset, Thermometer placement near door or vents
How to Fix / Troubleshooting
Safety: Unplug the unit before moving sensors or panels.
Steps:
- 1. Verify measurement: Place a reliable thermometer in the center of the cabinet away from walls and door. Allow several hours for stabilization.
- 2. Check sensor placement: Ensure the cabinet sensor is mounted in its original location and not touching the evaporator or walls.
- 3. Replace sensor if needed: If the displayed temperature is consistently off by several degrees and the sensor is old, replace the La Sommeliere cabinet NTC sensor.
- 4. Adjust setpoint: If no calibration function exists, compensate by adjusting the setpoint up or down to achieve the desired actual temperature.