Lanbo Communication Error Between Display Board and Main Control Board

Display shows E6 and the control panel may be unresponsive or show erratic behavior.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged communication harness, Oxidized connectors at control or display board, Faulty display (UI) board, Failed main control board

How to Fix / Troubleshooting

Disconnect power before removing the control panel or accessing the electronics.

E6 typically indicates a communication problem between the user interface and the main control board.

  • 1. Power cycle:
    • Unplug the cooler for 10 minutes.
    • Plug it back in and check if E6 clears.
  • 2. Access control panel:
    • Remove the screws securing the top/front control panel.
    • Carefully pull the panel forward to expose the wiring.
  • 3. Inspect harness and connectors:
    • Locate the multi-pin cable between the display board and main board.
    • Unplug and re-seat both ends several times to clean contacts.
    • Check for pinched or cut wires along the harness path.
  • 4. Check for moisture or corrosion:
    • Look for signs of condensation or liquid spills around the control area.
    • Dry gently with a clean cloth; do not use heat guns.
  • 5. Replace faulty board:
    • If wiring is intact and E6 persists, replace the Lanbo display (UI) board first, as it is usually easier and cheaper.
    • If that does not resolve the issue, the main control board may need replacement.