E7
Lanbo
Dual-Zone Communication or Zone Sensor Error
Display shows E7 and one temperature zone does not respond to setpoint changes.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed upper or lower zone sensor, Broken harness between zones, Faulty dual-zone control board, Incorrect zone configuration after power loss
How to Fix / Troubleshooting
Unplug the unit before accessing internal wiring.
On dual-zone Lanbo wine coolers, E7 often relates to a communication or sensor issue specific to one zone.
- 1. Identify affected zone:
- Note whether the upper or lower compartment is not cooling or not displaying correctly.
- 2. Check zone sensor connections:
- Remove interior panels in the affected zone.
- Locate the zone's temperature sensor and verify the connector is firmly seated.
- 3. Inspect inter-zone harness:
- Some models route wiring between zones; check for pinched or damaged cables at the divider.
- 4. Sensor test and replacement:
- Test the zone sensor resistance and compare to the working zone's sensor.
- Replace the Lanbo upper zone temperature sensor or lower zone temperature sensor if readings are abnormal.
- 5. Control board check:
- If sensors and wiring are good, the dual-zone main control board may be defective and should be replaced by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Upper Zone Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements