EC
Lanbo
General Cooling System Error
Display shows EC and the unit stops cooling or cycles off quickly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Compressor start failure, Overcurrent protection trip, Sealed system restriction, Control board compressor relay failure
How to Fix / Troubleshooting
Unplug the cooler before inspecting the compressor area.
EC is a generic error indicating the cooling system is not operating correctly.
- 1. Power reset:
- Unplug for 10 minutes and plug back in to clear transient faults.
- 2. Listen for compressor start:
- After plugging in, listen for a humming sound from the compressor.
- Repeated clicking without sustained running suggests a start problem.
- 3. Inspect start components:
- Remove the compressor cover and check the start relay/PTC and overload for damage.
- 4. Replace start device if faulty:
- Install a new Lanbo compressor start relay and overload if the old one is burned or rattles.
- 5. If compressor runs but no cooling:
- There may be a sealed system issue (low refrigerant, restriction, or failed compressor) requiring a professional technician.
- 6. If compressor never receives power:
- The main control board may have a failed compressor relay and need replacement.