EC
Lanbo General Cooling System Error

Display shows EC and the unit stops cooling or cycles off quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Compressor start failure, Overcurrent protection trip, Sealed system restriction, Control board compressor relay failure

How to Fix / Troubleshooting

Unplug the cooler before inspecting the compressor area.

EC is a generic error indicating the cooling system is not operating correctly.

  • 1. Power reset:
    • Unplug for 10 minutes and plug back in to clear transient faults.
  • 2. Listen for compressor start:
    • After plugging in, listen for a humming sound from the compressor.
    • Repeated clicking without sustained running suggests a start problem.
  • 3. Inspect start components:
    • Remove the compressor cover and check the start relay/PTC and overload for damage.
  • 4. Replace start device if faulty:
    • Install a new Lanbo compressor start relay and overload if the old one is burned or rattles.
  • 5. If compressor runs but no cooling:
    • There may be a sealed system issue (low refrigerant, restriction, or failed compressor) requiring a professional technician.
  • 6. If compressor never receives power:
    • The main control board may have a failed compressor relay and need replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay/PTC
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements