H1
Lanbo High Temperature Sensor Reading / Sensor Out of Range

Display shows H1 and the temperature reading is abnormally high even in a cool room.

Advertisements

Possible Causes

Sensor partially shorted, Sensor not in proper location, Warm air leak around door gasket, Control board misreading sensor

How to Fix / Troubleshooting

Unplug the cooler before moving sensors or panels.

H1 indicates the sensor is reading an unusually high temperature or is out of its normal range.

  • 1. Verify actual temperature:
    • Place an accurate thermometer inside the cabinet.
    • Compare the reading to the display.
  • 2. Check door seal:
    • Inspect the Lanbo door gasket for gaps, tears, or warping.
    • Close the door on a sheet of paper; if it pulls out easily, the seal may be leaking.
  • 3. Inspect sensor placement:
    • Ensure the cabinet sensor is not touching warm components or light fixtures.
    • Reposition it to the correct location if necessary.
  • 4. Replace sensor if readings are inaccurate:
    • If the thermometer shows normal temperature but the display shows H1, replace the cabinet temperature sensor.
  • 5. If problem persists:
    • The main control board may be misinterpreting sensor data and require replacement.