Lanbo
No Cooling / Compressor Not Starting
Wine cooler not cooling at all; interior is at room temperature and compressor is not running.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main control board, Failed compressor start relay or overload, Open thermal fuse, Defective compressor
How to Fix / Troubleshooting
Unplug the cooler before removing any covers.
- 1. Confirm power supply:
- Check that the outlet has power by plugging in another device.
- Verify the cooler's power cord is fully inserted and not damaged.
- 2. Check control settings:
- Ensure the unit is not in standby or demo mode.
- 3. Inspect compressor area:
- Remove the rear lower panel.
- Look for burned components on the main control board or around the compressor start relay.
- 4. Test start relay and overload:
- Remove them from the compressor and shake gently; rattling or burn marks indicate failure.
- Replace with a new Lanbo start relay/overload kit if defective.
- 5. If compressor still does not start and board is supplying no power:
- The main control board may be faulty and should be replaced.
- 6. If compressor hums loudly then trips:
- The compressor may be locked and require professional sealed-system service or replacement.