E7
Lanbopro Door Switch / Door Sensor Fault

Display shows E7 and the interior light or door switch functions erratically.

Advertisements

Possible Causes

Defective magnetic door switch, Misaligned door magnet, Broken door switch wiring, Faulty main control board input

How to Fix / Troubleshooting

Safety first: Disconnect power before working around the door frame wiring.

  • Identify door switch type: Many Lanbopro wine coolers use a magnetic reed switch in the cabinet frame and a magnet in the door.
  • Check door alignment: Ensure the door closes squarely and the magnet lines up with the switch area. Adjust door hinges if the door is sagging.
  • Test light behavior: With power on, open and close the door to see if the interior light turns on/off consistently. Then unplug before further work.
  • Inspect switch and wiring: Remove the inner trim near the switch location. Check the door switch and its wiring for damage or loose connections.
  • Replace faulty switch or magnet: If the switch is cracked or the magnet is missing/loose, replace the door switch assembly or resecure/replace the door magnet.
  • Control board check: If the switch and magnet are good but E7 persists, the main control board may have a faulty input circuit.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements