E8
Lanbopro
High Temperature Alarm / Overheat Protection Fault
Display shows E8 and the unit may not cool properly or may shut down unexpectedly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked ventilation around cabinet, Dirty condenser coils, Failed condenser fan motor, Ambient temperature above design limits
How to Fix / Troubleshooting
Safety first: Unplug the cooler before cleaning or servicing.
- Check installation: Verify that the Lanbopro wine cooler has the required clearance on sides, back, and top as specified in the manual. Do not enclose it tightly in cabinetry without proper ventilation.
- Clean condenser: Remove the rear lower panel and vacuum or brush dust from the condenser coils and surrounding area.
- Verify condenser fan: Briefly plug in the unit and check that the condenser fan motor runs whenever the compressor is on. Unplug again before touching components.
- Room temperature check: Ensure the cooler is not installed in a garage or area where ambient temperature exceeds the unit's rated range.
- Reset alarm: After improving ventilation and cleaning, unplug the unit for 5 minutes, then reconnect power to clear the E8 alarm.
- Replace fan if needed: If the condenser fan does not run, replace the condenser fan motor. Persistent E8 after these steps may indicate a failing compressor or control board; contact a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condenser Fan Motor
Check Price on Amazon