EC
Lanbopro General Cooling System Fault

Display shows EC and the unit is not cooling or is cooling very poorly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak in sealed system, Weak compressor, Blocked capillary tube, Severely dirty condenser coils

How to Fix / Troubleshooting

Safety first: Unplug the unit before inspection. Sealed system repairs involve refrigerant and should be performed by a licensed technician.

  • Basic checks: Confirm the temperature setpoints are correct and that doors are sealing properly. Ensure the unit has adequate ventilation.
  • Clean condenser: Remove the rear lower panel and clean the condenser coils thoroughly.
  • Compressor and fan operation: Briefly plug in the unit and verify that the compressor and condenser fan run. Unplug again before touching components.
  • Check for frost pattern: Remove the interior rear panel and inspect the evaporator coil. A normal system will show even frost across most of the coil after 10–15 minutes of run time. A partial frost pattern or no frost suggests a sealed system issue.
  • When to call a pro: If EC persists and you observe a weak frost pattern, warm evaporator, or oily residue on tubing (sign of leak), contact a professional refrigeration technician. They may need to repair leaks, evacuate, and recharge the system or replace the compressor.
Advertisements

Repair Difficulty

Professional Required 5/5
Advertisements