F1
Lanbopro Upper Zone Control Fault

Display shows F1 and the upper zone does not maintain the set temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Upper zone sensor failure, Upper zone damper or fan issue, Loose wiring to upper zone components, Main control board upper channel failure

How to Fix / Troubleshooting

Safety first: Disconnect power before servicing.

  • Sensor check: Follow E1 procedures to inspect and, if needed, replace the upper temperature sensor.
  • Upper fan/damper: On some dual-zone Lanbopro models, a small fan or damper moves cold air to the upper zone. Access the upper rear panel and verify the upper zone circulation fan runs and the damper (if present) is not stuck.
  • Wiring inspection: Check harnesses from the upper zone components to the main control board for loose or damaged wires.
  • Control board: If sensors and fans are good but F1 persists, replace the main control board.
Advertisements

Repair Difficulty

Hard 4/5