Lanbopro Insufficient Cooling / Partial Loss of Refrigeration

Wine cooler runs but does not get cold enough; interior stays above 60°F (15°C).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coils, Weak compressor, Low refrigerant charge from small leak, Evaporator fan not moving air

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning or removing panels.

  • Verify settings: Confirm the temperature is set to the desired level and not in a higher storage mode.
  • Clean condenser: Remove the rear lower panel and thoroughly clean the condenser coils with a soft brush and vacuum.
  • Check fans: With the panel off, briefly plug in the unit and ensure both the condenser fan and evaporator fan run when the compressor is on. Unplug again before touching.
  • Door seal: Inspect the door gasket for gaps or tears. Replace if it does not seal tightly all around.
  • Observe frost pattern: Remove the interior rear panel and check the evaporator coil. If only a small section frosts or there is no frost, a sealed system issue (leak or weak compressor) is likely and requires a professional technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Coil
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements