Possible Causes

Failed evaporator fan in warm zone, Blocked air duct between zones, Faulty thermistor for affected zone, Control board channel failure for that zone

How to Fix / Troubleshooting

Safety: Unplug the unit before removing interior panels.

Steps:

  • Identify design: Some dual-zone Magic Chef models share a single compressor with separate fans and ducts; others have independent cooling modules.
  • Check fan in warm zone: Open the door of the warm zone and listen for fan operation when cooling is called for. If silent, access and test the fan motor.
  • Inspect air ducts: Look for blocked vents or ducts between zones caused by bottles or debris.
  • Test thermistor for warm zone: Access the sensor for the affected zone and test resistance. Replace if out of range.
  • Control board: If fans and sensors are good, the control board may not be energizing the cooling components for that zone and should be replaced.