Magic Chef
Temperature Reading Out of Range or Sensor Disconnected
Display shows dashes ("--") instead of a temperature reading.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unplugged or broken temperature sensor, Sensor reading outside valid range due to extreme conditions, Faulty main control board
How to Fix / Troubleshooting
Safety: Unplug the unit before removing interior panels.
Steps:
- Normalize conditions: Ensure the cooler is in a normal room environment (not in freezing garage or very hot area). Allow several hours for internal temperature to stabilize.
- Inspect cabinet thermistor: Remove the interior sensor cover and verify the sensor is firmly attached and not dangling or broken.
- Check sensor connection at board: Access the main control board and confirm the sensor connector is fully seated.
- Test sensor: Use a multimeter to measure resistance. An open or shorted reading indicates a failed sensor that must be replaced.
- Replace sensor or board: If the sensor is bad, install a new cabinet thermistor. If the sensor tests good but the display still shows dashes, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements