Magic Chef
Compressor Control or Start Circuit Failure
Interior fan runs but compressor does not, and temperature slowly rises.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor start relay, Open compressor overload, Faulty main control board compressor output, Broken wire to compressor
How to Fix / Troubleshooting
Safety: Unplug the unit before touching compressor wiring. High voltage is present when powered.
Steps:
- Confirm symptom: Listen and feel: the interior fan runs, but the compressor is silent and cool to the touch after 15–20 minutes.
- Inspect start device: Remove the start relay/overload from the compressor and check for burn marks or rattling. Replace if suspect.
- Check wiring: Verify that wires from the control board to the compressor and start device are intact and firmly connected.
- Control board: If a new start device does not restore compressor operation, the main control board may not be sending power to the compressor and should be replaced.
- Professional diagnosis: If the compressor still does not run with a known-good board and start device, the compressor itself is likely failed and requires sealed system service.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Start Relay
Check Price on Amazon