dO
Maytag Door Switch or Door Ajar Sensor Fault

Display shows dO or “door” and an alarm sounds even when the door appears closed.

Advertisements

Possible Causes

Failed magnetic reed switch or mechanical door switch, Misaligned door magnet, Broken or loose door switch wiring, Faulty input circuit on control board

How to Fix / Troubleshooting

Safety: Disconnect power before working on the door switch or control panel.

  • 1. Check door closure: Ensure nothing is blocking the door from closing fully (shelves, bottles, gasket folds). Verify that the door is level and aligned with the cabinet.
  • 2. Inspect door gasket: Look for warped or torn gasket sections that prevent full closure. Replace the gasket if necessary.
  • 3. Locate door switch: Depending on the model, the switch may be a plunger-style switch in the frame or a magnetic reed switch hidden in the cabinet with a magnet in the door.
  • 4. Test the switch: With the unit unplugged, remove the switch or access its wiring. Use a multimeter to check continuity while pressing the plunger or placing a magnet near the reed switch. Replace the door switch if it does not change state.
  • 5. Check wiring to control board: Verify continuity from the switch to the main control board. Repair any broken or pinched wires.
  • 6. Control board input: If the switch and wiring are good, the control board may not be recognizing the closed signal. Replace the main control board if needed.
  • 7. Test alarm: Restore power and confirm that the door alarm no longer sounds when the door is closed and that the dO code is cleared.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements