E9
Maytag Temperature Calibration or Sensor Range Error

Wine cooler displays E9 and temperature cannot be adjusted or readings are obviously incorrect.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Out-of-range thermistor readings, Incorrect sensor installed, Control board calibration fault, Loose sensor connectors

How to Fix / Troubleshooting

Safety: Disconnect power before unplugging or replacing sensors.

  • 1. Confirm actual temperature: Place an accurate refrigerator thermometer inside the cooler and compare to the displayed temperature after several hours of stable operation.
  • 2. Inspect all thermistors: Access the cabinet, evaporator, and ambient sensors. Ensure each is properly mounted and connected. Look for mismatched or non-OEM sensors that may have been installed previously.
  • 3. Test sensor resistances: With the unit unplugged, disconnect each thermistor and measure resistance. Compare to the manufacturer’s NTC chart. Replace any sensor that is significantly out of range.
  • 4. Check connectors: Reseat all sensor connectors at the control board. Clean any corrosion with contact cleaner.
  • 5. Control board replacement: If all sensors test correctly and wiring is intact, the control board’s calibration or ADC (analog-to-digital converter) may be faulty. Replace the main control board.
  • 6. Verify operation: After reassembly, allow the cooler to run for several hours and confirm that the displayed temperature matches the thermometer and that E9 does not return.
Advertisements

Repair Difficulty

Hard 4/5