Control Panel Keypad Fault
Display shows F1 and the unit may not respond to temperature changes.
Advertisements
Possible Causes
Shorted or open keypad membrane, Damaged control panel ribbon cable, Faulty user interface board, Moisture intrusion into control panel
How to Fix / Troubleshooting
Safety: Disconnect power before removing the control panel.
- 1. Inspect for moisture: Look for condensation or liquid spills around the control panel. Dry the area thoroughly and allow the panel to air out for several hours.
- 2. Remove control panel: Carefully pry off the trim and remove screws securing the panel. Gently pull the panel forward to access the ribbon cable.
- 3. Reseat ribbon cable: Disconnect and reconnect the ribbon cable between the keypad and main control board. Ensure it is fully seated and not damaged.
- 4. Test operation: Restore power and check if F1 clears and buttons respond normally.
- 5. Replace keypad/UI board: If the error persists, replace the user interface or keypad assembly with a compatible Maytag part.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
User Interface Control Panel