F1
Maytag Control Panel Keypad Fault

Display shows F1 and the unit may not respond to temperature changes.

Advertisements

Possible Causes

Shorted or open keypad membrane, Damaged control panel ribbon cable, Faulty user interface board, Moisture intrusion into control panel

How to Fix / Troubleshooting

Safety: Disconnect power before removing the control panel.

  • 1. Inspect for moisture: Look for condensation or liquid spills around the control panel. Dry the area thoroughly and allow the panel to air out for several hours.
  • 2. Remove control panel: Carefully pry off the trim and remove screws securing the panel. Gently pull the panel forward to access the ribbon cable.
  • 3. Reseat ribbon cable: Disconnect and reconnect the ribbon cable between the keypad and main control board. Ensure it is fully seated and not damaged.
  • 4. Test operation: Restore power and check if F1 clears and buttons respond normally.
  • 5. Replace keypad/UI board: If the error persists, replace the user interface or keypad assembly with a compatible Maytag part.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

User Interface Control Panel
Check Price on Amazon

We may earn a commission from links on this page.