Maytag Stuck Door Switch or Control Logic Fault

Interior light stays on even when the door is closed, causing warming inside.

Advertisements

Possible Causes

Door switch stuck in open position, Misaligned door not pressing switch, Shorted light control circuit on board

How to Fix / Troubleshooting

Safety: Unplug the unit before working on the door switch or control board.

  • 1. Verify door alignment: Ensure the door fully closes and contacts the switch plunger. Adjust hinges if needed.
  • 2. Test door switch: Remove and test for proper open/closed continuity. Replace if it does not change state.
  • 3. Inspect control board: If the switch is good but the light remains on, the control board may be stuck driving the light. Replace the main control board.
  • 4. Temporary mitigation: Remove the light bulb or disconnect the LED module until repairs are completed to prevent overheating the cabinet.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.