Maytag
Stuck Door Switch or Control Logic Fault
Interior light stays on even when the door is closed, causing warming inside.
Advertisements
Possible Causes
Door switch stuck in open position, Misaligned door not pressing switch, Shorted light control circuit on board
How to Fix / Troubleshooting
Safety: Unplug the unit before working on the door switch or control board.
- 1. Verify door alignment: Ensure the door fully closes and contacts the switch plunger. Adjust hinges if needed.
- 2. Test door switch: Remove and test for proper open/closed continuity. Replace if it does not change state.
- 3. Inspect control board: If the switch is good but the light remains on, the control board may be stuck driving the light. Replace the main control board.
- 4. Temporary mitigation: Remove the light bulb or disconnect the LED module until repairs are completed to prevent overheating the cabinet.
Advertisements
Repair Difficulty
Easy
2/5