Maytag
Defrost Drain Blockage or Condensation Management Issue
Water pooling at the bottom of the wine cooler interior.
Advertisements
Possible Causes
Clogged defrost drain tube, Drain trough frozen over, Cabinet not level causing water to collect, Door gasket leak causing excess moisture
How to Fix / Troubleshooting
Safety: Unplug the unit before removing interior panels.
- 1. Locate drain trough: Remove the interior rear panel to find the drain trough beneath the evaporator.
- 2. Clear drain hole: Use a small plastic probe or pipe cleaner to gently clear the drain opening. Do not use sharp metal tools.
- 3. Flush drain tube: Use a turkey baster or syringe with warm water to flush the drain line until water flows freely into the drain pan under the unit.
- 4. Level the cabinet: Adjust leveling legs so water flows toward the drain.
- 5. Check door gasket: Repair or replace if it is allowing warm, moist air into the cabinet.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Defrost Drain Tube
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements