Maytag
Control Not Satisfying Setpoint or Sensor Drift
Wine cooler runs constantly and never seems to shut off, though temperature is acceptable.
Advertisements
Possible Causes
Thermistor reading slightly warm, Control board hysteresis too wide, Door gasket leak, Poor insulation or high ambient temperature
How to Fix / Troubleshooting
Safety: Unplug the unit before testing sensors or adjusting door components.
- 1. Confirm actual temperature: Use a thermometer to verify that the interior is at the desired temperature.
- 2. Inspect door gasket and cabinet: Repair any leaks that allow warm air in.
- 3. Test thermistor: Replace if readings are off compared to actual temperature.
- 4. Consider ambient conditions: If the cooler is in a very warm room, continuous running may be normal. Improve room cooling or ventilation if possible.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Cabinet Temperature Thermistor
Check Price on Amazon
We may earn a commission from links on this page.