Miele
Compressor Start Failure
Clicking or ticking noise from the rear of the unit; compressor attempts to start but shuts off repeatedly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak compressor start relay/PTC, Failing compressor drawing high current, Defective overload protector, Low supply voltage
How to Fix / Troubleshooting
Safety first: Unplug the unit and allow the compressor to cool before touching. Mains voltage is present at the start components.
- 1. Verify supply voltage:
- Ensure the outlet provides stable voltage and is not shared with heavy loads.
- 2. Inspect start components:
- Access the compressor compartment and remove the start relay/PTC and overload.
- Check for burn marks or a burnt smell.
- 3. Replace start device:
- If the relay/PTC shows signs of damage or rattles loosely, replace it with the correct Miele part.
- 4. Test compressor (advanced):
- Measure winding resistances; if they are out of spec or shorted, the compressor is likely defective.
- 5. Professional service: If a new start device does not resolve the issue, the compressor may need replacement by a refrigeration-certified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Start Relay / PTC
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements