F10
Miele Interior Lighting / Door Logic Fault

Display shows F10 and the interior light remains on or off incorrectly; door status on display may be wrong.

Advertisements

Possible Causes

Shorted LED light module, Failed light driver circuit on main board, Incorrect door switch signal, Wiring short in light circuit

How to Fix / Troubleshooting

Safety first: Disconnect power before working on lighting or door circuits. LED drivers operate at mains or high DC voltage.

F10 is associated with interior lighting or door logic errors.

  • 1. Observe light behavior:
    • Check if the interior light stays on with the door closed or never turns on with the door open.
  • 2. Check door switch function:
    • Verify that the door contact switch correctly signals open/closed (see F7 procedure).
  • 3. Inspect LED module:
    • Locate the interior LED light module(s) in the cabinet ceiling or side walls.
    • Check for discoloration, burn marks, or flickering.
  • 4. Disconnect suspect light module:
    • With power off, unplug the LED module from its connector.
    • Restore power briefly to see if F10 clears (do not leave panels open unattended).
  • 5. Replace faulty LED module:
    • If F10 clears when the module is disconnected, replace the LED light module with the correct Miele part.
  • 6. Control board check: If lights and door switch are good but F10 persists, the light driver on the main control board may be defective and requires board replacement by a technician.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Interior LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.