F15
Miele
Secondary Zone Temperature Sensor Failure
Display shows F15 and one temperature zone shows dashes or cannot display a valid temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective NTC sensor in upper or lower zone, Broken sensor wiring, Corroded connector at zone interface, Faulty sensor input on control board
How to Fix / Troubleshooting
Safety first: Disconnect power before removing interior panels or accessing wiring.
F15 indicates a temperature sensor fault in one of the wine cooler’s zones.
- 1. Determine which zone is affected:
- Check which zone shows dashes or abnormal readings.
- 2. Locate the zone sensor:
- Find the small sensor cover on the wall of the affected zone.
- Remove the cover to access the NTC sensor.
- 3. Inspect and test:
- Check the sensor and wiring for damage or moisture.
- Disconnect and measure resistance at room temperature; open or shorted readings indicate failure.
- 4. Replace the sensor:
- Order the correct Miele zone temperature sensor for your model and zone.
- Install in the same location and route wiring as original.
- 5. Check connectors at control board:
- Reseat the zone sensor connector on the main PCB.
- 6. If F15 remains with a new sensor: The control board’s sensor channel may be defective and should be replaced by a professional.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Zone Temperature Sensor (NTC)
Check Price on Amazon