F16
Miele Temperature Measurement Range / Calibration Fault

Display shows F16 and the unit may show erratic or impossible temperature values (e.g., -40°C or 99°C).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted or open NTC sensor, Incorrect sensor type fitted, Control board ADC failure, Wiring short to chassis

How to Fix / Troubleshooting

Safety first: Unplug the appliance before testing sensors or wiring.

F16 indicates that a temperature reading is outside the valid range expected by the control.

  • 1. Identify which sensor is affected:
    • Compare displayed temperatures for each zone and ambient; the one showing extreme values is suspect.
  • 2. Test the suspect sensor:
    • Access the sensor (cabinet, zone, or evaporator) and disconnect it.
    • Measure resistance at room temperature; if it reads near 0 Ω or OL, the sensor is faulty.
  • 3. Inspect wiring:
    • Look for pinched or rubbed-through insulation causing shorts to the cabinet.
  • 4. Replace with correct sensor:
    • Use only the Miele-specified NTC sensor for your model; mixing sensor types can cause F16.
  • 5. If all sensors test correctly: The analog-to-digital converter on the main board may be defective; board replacement is required and should be done by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements