No Power or Main Control Failure
Wine cooler not cooling at all; interior is at room temperature, compressor and fans are not running.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped circuit breaker or blown fuse, Faulty power cord, Failed main control board, Open thermal fuse in power circuit
How to Fix / Troubleshooting
Safety: Always disconnect the unit before inspecting wiring. Do not bypass safety devices.
- Verify power source: Plug a lamp or tester into the same outlet to confirm it has power. Reset any tripped breaker or replace a blown house fuse.
- Inspect power cord: Check the Monogram power cord for cuts, burns, or crushed sections. If damaged, replace the cord with the correct part.
- Check internal fuses: Remove the rear access panel and inspect the main control board for onboard fuses. Test continuity with a multimeter and replace only with identical rated fuses if blown.
- Look for board damage: If the board shows burnt areas or swollen components, replace the main control board.
- Door switch and UI: Ensure the display lights when plugged in. If the display is dead but outlet has power, the issue is likely in the control board or power wiring.