Monogram Inaccurate Temperature Control or Short Cycling

Wine cooler temperature fluctuates widely, causing wine to warm and cool repeatedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty temperature sensor, Poor sensor placement, Control board hysteresis too narrow, Evaporator icing affecting airflow

How to Fix / Troubleshooting

Safety: Unplug before accessing sensors or panels.

  • Verify with thermometer: Place a data-logging or min/max thermometer inside to confirm fluctuations.
  • Inspect sensor and airflow: Ensure the cabinet thermistor is properly mounted and not directly in the coldest airflow or touching metal.
  • Check for frost: Remove the interior panel and inspect the evaporator for icing that could block airflow. If present, troubleshoot the defrost system.
  • Replace sensor: If the thermistor readings are erratic when tested, replace it.
  • Control board: If hardware is good but fluctuations persist, the main control board’s control algorithm may be faulty and require replacement.

Stable temperature is critical for wine storage; monitor after repair to ensure consistency.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Temperature Sensor (NTC Thermistor)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements