Montpellier Thermostat / Temperature Control Failure

Wine cooler overcooling, bottles very cold or partially frozen even at moderate set temperature

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor out of calibration, Sensor not properly attached to evaporator or cabinet wall, Stuck compressor relay on main PCB, Control board logic fault

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors or the control board.

  • Verify with thermometer: Place an accurate thermometer inside and compare to the set and displayed temperatures. Significant discrepancy indicates a control issue.
  • Inspect sensor placement: Remove the interior rear panel and confirm the cabinet or evaporator sensor is correctly clipped to the surface it is meant to measure, not hanging in free air or touching the evaporator directly if not designed to.
  • Replace suspect sensor: If the sensor is misreading, install a new Montpellier-compatible NTC sensor in the correct location.
  • Check compressor cycling: Observe whether the compressor ever turns off. If it runs constantly even when the cabinet is very cold, the relay on the main PCB may be stuck closed. In that case, the main control board should be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon