mQuvée
Temperature Display Calibration Error
Display shows correct temperature but bottles feel warmer or colder than indicated.
Advertisements
Possible Causes
Sensor not located in representative air stream, Sensor touching cold evaporator surface, Control board calibration drift, User thermometer placement near door or light
How to Fix / Troubleshooting
Safety: Unplug the unit before adjusting sensor placement.
- Verify with multiple thermometers: Use at least two accurate thermometers placed in the middle of the cabinet away from walls and door.
- Sensor placement: Ensure the cabinet sensor is mounted where air circulates freely, not directly on the evaporator or near the door.
- Reposition sensor: If necessary, gently move the sensor slightly away from very cold surfaces while keeping it secured.
- PCB replacement: If a consistent offset remains and affects storage, the main control PCB may require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Cabinet NTC Temperature Sensor
Check Price on Amazon