E11
mQuvée Door Switch / Door Sensor Fault

Display shows E11 and the door open alarm may sound even when the door is closed.

Advertisements

Possible Causes

Misaligned magnetic door switch, Failed reed switch on cabinet frame, Broken door switch wiring, Faulty door input circuit on main control PCB

How to Fix / Troubleshooting

Safety: Unplug the unit before working around the door switch wiring.

  • Check door closure: Ensure the door closes fully and the gasket is not obstructed by shelves or bottles.
  • Locate door sensor: On many mQuvée models, a magnetic reed switch is mounted in the cabinet frame with a magnet in the door.
  • Alignment: Verify that the magnet in the door lines up directly with the reed switch when closed. Adjust the door or switch position slightly if needed.
  • Test with magnet: With the door open and power on, place a small magnet over the reed switch location. If the alarm stops and E11 clears, the door magnet is weak or misaligned; replace or reposition it.
  • Inspect wiring: Remove the inner trim to access the switch wiring. Repair any broken or loose connections.
  • Replace switch: If the reed switch does not respond to a magnet, replace it with a compatible mQuvée door switch.
  • PCB fault: If a new switch and magnet do not resolve E11, the main control PCB door input may be defective and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Reed Switch
Check Price on Amazon

We may earn a commission from links on this page.