mQuvée Lower Zone Cooling Failure

Upper zone cools properly but lower zone is warm (dual-zone model).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed lower zone evaporator fan, Blocked air duct between zones, Faulty lower zone temperature sensor, Partial refrigerant restriction to lower evaporator

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal components.

  • Check setpoints: Confirm the lower zone is set to a cooler temperature than ambient and not accidentally turned off.
  • Fan operation: Listen for airflow in the lower zone. If absent, access the lower evaporator fan and test/replace it.
  • Inspect air ducts: Ensure vents between zones are not blocked by bottles or shelves.
  • Sensor check: Test or replace the lower zone NTC sensor if the display shows incorrect or unstable temperatures.
  • Sealed system: If the fan and sensor are good but the lower evaporator does not frost while the upper does, a sealed system restriction may exist and requires a refrigeration technician.