mQuvée
Thermostat / Temperature Control Calibration Fault
Wine cooler interior too cold; bottles or labels show signs of freezing even at moderate set temperatures.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty NTC temperature sensor reading too warm, Stuck relay on main control PCB keeping compressor on, Miscalibrated control board, Sensor not properly attached to evaporator or cabinet wall
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing sensors or PCB.
- Verify with thermometer: Place an independent thermometer inside to confirm actual temperature versus display.
- Check sensor placement: Ensure cabinet and evaporator sensors are firmly attached and not hanging in free air or touching very cold metal directly.
- Inspect wiring: Look for damaged sensor wires that could cause incorrect readings.
- Replace suspect sensor: If readings are clearly off, replace the cabinet NTC sensor with the correct mQuvée part.
- Control board: If freezing persists with a new sensor, the main control PCB may be misreading or stuck driving the compressor. Replace the PCB.
- Interim measure: Raise the set temperature a few degrees and monitor until permanent repairs are made.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.