NEEDONE
Temperature Calibration / Sensor Placement Issue
Display shows temperature but actual interior temperature is significantly different.
Advertisements
Possible Causes
Sensor not in correct location, Sensor touching evaporator coil, Sensor out of calibration, Control board misreading sensor
How to Fix / Troubleshooting
Safety first: Unplug the unit before moving sensors or panels.
- Verify with thermometer: Place an accurate thermometer in the center of the compartment and compare after several hours.
- Inspect sensor placement: Locate the compartment sensor and ensure it is not touching the evaporator coil or directly in the airflow of the fan. It should sense average air temperature.
- Reposition sensor: If necessary, gently reposition or re-clip the sensor to its proper location.
- Replace sensor: If readings remain inaccurate, replace the sensor with a NEEDONE-compatible NTC probe.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Compartment Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.