H1
NEEDONE High Temperature Alarm Condition

Display shows H1 and the temperature reading is extremely high or flashing.

Advertisements

Possible Causes

Door left open, Recent warm loading of bottles, Failed evaporator fan, Blocked air vents between zones, Refrigeration system fault

How to Fix / Troubleshooting

Safety first: This is typically an alarm, not an electrical fault, but always unplug before removing panels.

  • Check doors: Ensure the door is fully closed and the gasket is sealing all around. Remove any bottles preventing full closure.
  • Allow recovery: If you recently loaded many warm bottles, allow 12–24 hours for the temperature to stabilize. Keep the door closed as much as possible.
  • Verify fan operation: Listen for the internal fan when the compressor is running. If silent, inspect the evaporator fan as described in the E6 procedure.
  • Check vents: Make sure air vents between upper and lower zones are not blocked by bottles or shelves.
  • Monitor: If the temperature does not drop and H1 persists after several hours, further diagnosis of the cooling system (compressor, refrigerant, sensors) is needed.
Advertisements

Repair Difficulty

Easy 2/5