Hi
NEEDONE
Maximum Temperature Limit / Sensor Out-of-Range
Display shows Hi and the cooler cannot be set to a higher temperature or shows an unrealistic high reading.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open temperature sensor circuit, Disconnected sensor harness, Control board misreading sensor, Door left open causing prolonged high temp alarm
How to Fix / Troubleshooting
Safety first: Disconnect power before removing panels.
- Door and load check: Ensure the door is closing properly and that the unit is not overloaded with warm bottles.
- Sensor inspection: Access the compartment sensor as in E1/E2. Check for a broken or disconnected sensor.
- Harness check: Follow the sensor wires to the main control board and reseat the connector.
- Replace sensor: If the sensor is open or damaged, replace it with the correct NEEDONE NTC probe.
- Control board: If a new sensor does not resolve Hi, the main control board may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Compartment Temperature Sensor