Hi
NEEDONE Maximum Temperature Limit / Sensor Out-of-Range

Display shows Hi and the cooler cannot be set to a higher temperature or shows an unrealistic high reading.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open temperature sensor circuit, Disconnected sensor harness, Control board misreading sensor, Door left open causing prolonged high temp alarm

How to Fix / Troubleshooting

Safety first: Disconnect power before removing panels.

  • Door and load check: Ensure the door is closing properly and that the unit is not overloaded with warm bottles.
  • Sensor inspection: Access the compartment sensor as in E1/E2. Check for a broken or disconnected sensor.
  • Harness check: Follow the sensor wires to the main control board and reseat the connector.
  • Replace sensor: If the sensor is open or damaged, replace it with the correct NEEDONE NTC probe.
  • Control board: If a new sensor does not resolve Hi, the main control board may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Compartment Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.