Neff
Stuck Door Switch or Control Logic Fault
Interior light stays on even when the door is closed, causing the cabinet to warm up.
Advertisements
Possible Causes
Misaligned door magnet, Stuck mechanical door switch, Faulty reed switch, Main control PCB not recognizing door closed state
How to Fix / Troubleshooting
Safety: Unplug the unit before adjusting switches or magnets.
Steps:
- Check door alignment: Ensure the cabinet is level and the door closes squarely against the frame.
- Inspect magnet: Verify that the door magnet is present and aligned with the frame sensor. Reposition or replace if missing.
- Test switch: Manually operate the switch or place a magnet over the reed sensor. If the light does not go off, replace the door switch assembly.
- Control board: If a new switch does not resolve the issue, the main control PCB may be faulty and should be replaced by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch / Reed Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements