dE
NutriChef
Door Switch / Door Ajar Detection Fault
Display shows dE or door icon flashes; interior light may stay on and cooling may stop intermittently.
Advertisements
Possible Causes
Misaligned door magnet or reed switch, Failed door switch sensor on control board, Loose door switch wiring, Warped door not closing fully
How to Fix / Troubleshooting
Safety: Unplug the cooler before adjusting internal switches.
Steps:
- 1. Check door closure: Ensure the door closes fully and the gasket makes uniform contact all around. Look for bottles or shelves preventing full closure.
- 2. Inspect door magnet: Many NutriChef wine coolers use a magnetic reed switch. Check that the magnet strip in the door frame is intact and aligned with the switch location.
- 3. Locate door switch: The reed switch is often behind the front frame near the top or side. Access may require removing the front trim or control panel.
- 4. Test switch: With the unit unplugged, disconnect the switch leads and test continuity with a multimeter while placing a magnet near the switch. Replace the switch if it does not change state.
- 5. Adjust alignment: If the switch works but does not detect the door, adjust the door hinges or gently reposition the magnet (if separate) so it lines up with the switch.
- 6. Control board: If the switch and magnet are good but dE persists, the door-sense circuit on the main control board may be faulty and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Reed Switch / Door Ajar Sensor
Check Price on Amazon