E7
NutriChef User Interface / Touch Panel Communication Error

Display shows E7 and the unit may not power on correctly or buttons do not respond.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose ribbon cable between display board and main control board, Damaged touch control PCB, Moisture intrusion into control panel, Faulty main control board communication circuit

How to Fix / Troubleshooting

Safety: Unplug the cooler before opening the control panel.

Steps:

  • 1. Inspect exterior: Check the control panel area for signs of liquid spills or condensation. Dry the surface thoroughly.
  • 2. Access control panel: Remove the screws securing the top or front trim to access the display/touch PCB. Carefully lift the panel to avoid tearing the ribbon cable.
  • 3. Reseat ribbon cable: Disconnect and reconnect the flat ribbon cable between the display board and the main control board. Ensure it is fully inserted and locked.
  • 4. Check for corrosion: Examine the display PCB for corrosion, burnt spots, or cracked solder joints. Light corrosion can sometimes be cleaned with isopropyl alcohol and a soft brush (with power disconnected and ample drying time).
  • 5. Test operation: Reassemble enough to safely power the unit and test buttons. If E7 remains and buttons are unresponsive, the display/touch PCB may need replacement.
  • 6. Replace control board if needed: If a new display board does not resolve E7, the main control board is likely at fault and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Display / Touch Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements